FDSNWS-Station Data:

Network Code Name Latitude Longitude Elevation [m] Status Start End Created
IV TREM ISOLE TREMITI - SAN NICOLA 42.123000 15.510000 120.00 open 2014/6/12 None 2014/6/12

FDSNWS-Station Instrumentation Data:

Channel Sensor type Sensor description Sensor model Sensor manufacturer Datalogger Sensitivity value Sensitivity frequency Input units name Output units name
HHE n/a NANOMETRICS TRILLIUM-120C n/a n/a NANOMETRICS TRIDENT-FS-40-VPP-SG-1 299640000.0 1.0 m/s count
HHE n/a NANOMETRICS TRILLIUM-120C n/a n/a INGV GAIA2-FS-40-VPP 235646000.0 1.0 m/s count
HHN n/a NANOMETRICS TRILLIUM-120C n/a n/a NANOMETRICS TRIDENT-FS-40-VPP-SG-1 299640000.0 1.0 m/s count
HHN n/a NANOMETRICS TRILLIUM-120C n/a n/a INGV GAIA2-FS-40-VPP 235646000.0 1.0 m/s count
HHZ n/a NANOMETRICS TRILLIUM-120C n/a n/a NANOMETRICS TRIDENT-FS-40-VPP-SG-1 299640000.0 1.0 m/s count
HHZ n/a NANOMETRICS TRILLIUM-120C n/a n/a INGV GAIA2-FS-40-VPP 235646000.0 1.0 m/s count
HNE n/a KINEMETRICS EPISENSOR n/a n/a INGV GAIA2-FS-40-VPP 320770.0 0.2 m/s**2 count
HNN n/a KINEMETRICS EPISENSOR n/a n/a INGV GAIA2-FS-40-VPP 320770.0 0.2 m/s**2 count
HNZ n/a KINEMETRICS EPISENSOR n/a n/a INGV GAIA2-FS-40-VPP 320770.0 0.2 m/s**2 count
HHZ n/a Trillium Compact, 120 s, 754 V/m/s Trillium Compact 120 (Vault, Posthole, OBS) Nanometrics Centaur, 40 vpp (gain 1), 100 sps, DC removal filter off, Linear phase 301720003.762 1.0 m/s count
HHN n/a Trillium Compact, 120 s, 754 V/m/s Trillium Compact 120 (Vault, Posthole, OBS) Nanometrics Centaur, 40 vpp (gain 1), 100 sps, DC removal filter off, Linear phase 301720003.762 1.0 m/s count
HHE n/a Trillium Compact, 120 s, 754 V/m/s Trillium Compact 120 (Vault, Posthole, OBS) Nanometrics Centaur, 40 vpp (gain 1), 100 sps, DC removal filter off, Linear phase 301720003.762 1.0 m/s count
HNZ n/a Episensor, DC to >200 Hz, 20V differential full scale voltage, 2g clip level Episensor (ES-T, ES-U, ES-U2, DS-DH, SBEPI), +/- 20V Differential Kinemetrics Centaur, 40 vpp (gain 1), 200 sps, DC removal filter off, Linear phase 407880.204821 1.0 m/s**2 count
HNN n/a Episensor, DC to >200 Hz, 20V differential full scale voltage, 2g clip level Episensor (ES-T, ES-U, ES-U2, DS-DH, SBEPI), +/- 20V Differential Kinemetrics Centaur, 40 vpp (gain 1), 200 sps, DC removal filter off, Linear phase 407880.204821 1.0 m/s**2 count
HNE n/a Episensor, DC to >200 Hz, 20V differential full scale voltage, 2g clip level Episensor (ES-T, ES-U, ES-U2, DS-DH, SBEPI), +/- 20V Differential Kinemetrics Centaur, 40 vpp (gain 1), 200 sps, DC removal filter off, Linear phase 407880.204821 1.0 m/s**2 count

Basic Data:

Description

Owner Data:

Firstname Lastname Department Agency City Street Country Phone Email
n/a n/a n/a n/a n/a n/a n/a n/a n/a

Morphology Data:

Description
Geological Unit Morphology Class Ground Type EC8 Groundwater Depth [m] Vs 30 [m/s] f0 [Hz] Amp(f0) Basin Flag Bedrock Depth [m]
0 0 0 0 False 0

Housing Data:

Description
Housing Class In Building? Number of storeys Distance to building
True 0 0

Borehole Data:

Depth [m]
0

Borehole Layers:

Description Top depth [m] Bottom depth [m]