| Network | Code | Name | Latitude | Longitude | Elevation [m] | Status | Start | End | Created |
|---|---|---|---|---|---|---|---|---|---|
| G | COYC | Coyhaique, Chile | -45.572990 | -72.081390 | 235.00 | open | 2004/12/17 | 2500/12/31 | 2004/12/17 |
| Channel | Sensor type | Sensor description | Sensor model | Sensor manufacturer | Datalogger | Sensitivity value | Sensitivity frequency | Input units name | Output units name |
|---|---|---|---|---|---|---|---|---|---|
| BH1 | n/a | STRECKEISEN STS1 | n/a | n/a | n/a | 2399140000.0 | 0.01 | m/s | counts |
| BH2 | n/a | STRECKEISEN STS1 | n/a | n/a | n/a | 2302670000.0 | 0.01 | m/s | counts |
| BHZ | n/a | STRECKEISEN STS1 | n/a | n/a | n/a | 2518680000.0 | 0.01 | m/s | counts |
| HNE | n/a | Kinemetrics FBA ES-T | n/a | n/a | n/a | 427693.0 | 1.0 | m/s**2 | counts |
| HNN | n/a | Kinemetrics FBA ES-T | n/a | n/a | n/a | 427693.0 | 1.0 | m/s**2 | counts |
| HNZ | n/a | Kinemetrics FBA ES-T | n/a | n/a | n/a | 427693.0 | 1.0 | m/s**2 | counts |
| LDI | n/a | Vaisala PTB110 Analog Barometer | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
| LKI | n/a | EE08 Temperature + Humidity Sensor | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
| BHE | n/a | STRECKEISEN STS2 | n/a | n/a | n/a | 2516640000.0 | 0.03 | m/s | counts |
| BHN | n/a | STRECKEISEN STS2 | n/a | n/a | n/a | 2516640000.0 | 0.03 | m/s | counts |
| BHZ | n/a | STRECKEISEN STS2 | n/a | n/a | n/a | 2516640000.0 | 0.03 | m/s | counts |
| LHE | n/a | STRECKEISEN STS2 | n/a | n/a | n/a | 2495030000.0 | 0.03 | m/s | counts |
| LHN | n/a | STRECKEISEN STS2 | n/a | n/a | n/a | 2495030000.0 | 0.03 | m/s | counts |
| LHZ | n/a | STRECKEISEN STS2 | n/a | n/a | n/a | 2495030000.0 | 0.03 | m/s | counts |
| VHE | n/a | STRECKEISEN STS2 | n/a | n/a | n/a | 2487880000.0 | 0.03 | m/s | counts |
| VHN | n/a | STRECKEISEN STS2 | n/a | n/a | n/a | 2487880000.0 | 0.03 | m/s | counts |
| VHZ | n/a | STRECKEISEN STS2 | n/a | n/a | n/a | 2487880000.0 | 0.03 | m/s | counts |
| BHE | n/a | STRECKEISEN STS1 + METROZET E300 Electronics | n/a | n/a | n/a | 4536670000.0 | 0.03 | m/s | counts |
| BHN | n/a | STRECKEISEN STS1 + METROZET E300 Electronics | n/a | n/a | n/a | 4513180000.0 | 0.03 | m/s | counts |
| BHZ | n/a | STRECKEISEN STS1 + METROZET E300 Electronics | n/a | n/a | n/a | 5791630000.0 | 0.03 | m/s | counts |
| LHE | n/a | STRECKEISEN STS1 + METROZET E300 Electronics | n/a | n/a | n/a | 4497710000.0 | 0.03 | m/s | counts |
| LHN | n/a | STRECKEISEN STS1 + METROZET E300 Electronics | n/a | n/a | n/a | 4474430000.0 | 0.03 | m/s | counts |
| LHZ | n/a | STRECKEISEN STS1 + METROZET E300 Electronics | n/a | n/a | n/a | 5741900000.0 | 0.03 | m/s | counts |
| VHE | n/a | STRECKEISEN STS1 + METROZET E300 Electronics | n/a | n/a | n/a | 4484820000.0 | 0.03 | m/s | counts |
| VHN | n/a | STRECKEISEN STS1 + METROZET E300 Electronics | n/a | n/a | n/a | 4461600000.0 | 0.03 | m/s | counts |
| VHZ | n/a | STRECKEISEN STS1 + METROZET E300 Electronics | n/a | n/a | n/a | 5725440000.0 | 0.03 | m/s | counts |
| BHE | n/a | STRECKEISEN STS2 | n/a | n/a | n/a | 629161000.0 | 0.03 | m/s | counts |
| BHN | n/a | STRECKEISEN STS2 | n/a | n/a | n/a | 629161000.0 | 0.03 | m/s | counts |
| BHZ | n/a | STRECKEISEN STS2 | n/a | n/a | n/a | 629161000.0 | 0.03 | m/s | counts |
| LHE | n/a | STRECKEISEN STS2 | n/a | n/a | n/a | 623758000.0 | 0.03 | m/s | counts |
| LHN | n/a | STRECKEISEN STS2 | n/a | n/a | n/a | 623758000.0 | 0.03 | m/s | counts |
| LHZ | n/a | STRECKEISEN STS2 | n/a | n/a | n/a | 623758000.0 | 0.03 | m/s | counts |
| VHE | n/a | STRECKEISEN STS2 | n/a | n/a | n/a | 621970000.0 | 0.03 | m/s | counts |
| VHN | n/a | STRECKEISEN STS2 | n/a | n/a | n/a | 621970000.0 | 0.03 | m/s | counts |
| VHZ | n/a | STRECKEISEN STS2 | n/a | n/a | n/a | 621970000.0 | 0.03 | m/s | counts |
| BHE | n/a | STRECKEISEN STS1 + METROZET E300 Electronics | n/a | n/a | n/a | 4536570000.0 | 0.01 | m/s | counts |
| BHN | n/a | STRECKEISEN STS1 + METROZET E300 Electronics | n/a | n/a | n/a | 4513080000.0 | 0.01 | m/s | counts |
| BHZ | n/a | STRECKEISEN STS1 + METROZET E300 Electronics | n/a | n/a | n/a | 5791510000.0 | 0.01 | m/s | counts |
| LHE | n/a | STRECKEISEN STS1 + METROZET E300 Electronics | n/a | n/a | n/a | 4530470000.0 | 0.01 | m/s | counts |
| LHN | n/a | STRECKEISEN STS1 + METROZET E300 Electronics | n/a | n/a | n/a | 4507010000.0 | 0.01 | m/s | counts |
| LHZ | n/a | STRECKEISEN STS1 + METROZET E300 Electronics | n/a | n/a | n/a | 5783720000.0 | 0.01 | m/s | counts |
| Description |
|---|
| Firstname | Lastname | Department | Agency | City | Street | Country | Phone | |
|---|---|---|---|---|---|---|---|---|
| n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
| Description |
|---|
| Geological Unit | Morphology Class | Ground Type EC8 | Groundwater Depth [m] | Vs 30 [m/s] | f0 [Hz] | Amp(f0) | Basin Flag | Bedrock Depth [m] |
|---|---|---|---|---|---|---|---|---|
| 0 | 0 | 0 | 0 | False | 0 |
| Description |
|---|
| Housing Class | In Building? | Number of storeys | Distance to building |
|---|---|---|---|
| True | 0 | 0 |
| Depth [m] |
|---|
| 0 |
| Description | Top depth [m] | Bottom depth [m] |
|---|