FDSNWS-Station Data:

Network Code Name Latitude Longitude Elevation [m] Status Start End Created
FR WALT Westhalten 47.965735 7.276520 373.00 open 2016/9/18 2500/12/31 2016/9/18

FDSNWS-Station Instrumentation Data:

Channel Sensor type Sensor description Sensor model Sensor manufacturer Datalogger Sensitivity value Sensitivity frequency Input units name Output units name
HNE n/a TITAN n/a n/a n/a 213909.0 1.0 m/s**2 counts
HNN n/a TITAN n/a n/a n/a 213909.0 1.0 m/s**2 counts
HNZ n/a TITAN n/a n/a n/a 213909.0 1.0 m/s**2 counts
BHE n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 3.16376049e+08 1 m/s count
BHN n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 3.16376049e+08 1 m/s count
BHZ n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 3.16376049e+08 1 m/s count
HHE n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 3.16376049e+08 1 m/s count
HHN n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 3.16376049e+08 1 m/s count
HHZ n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 3.16376049e+08 1 m/s count
LHE n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 3.16376049e+08 0.5 m/s count
LHN n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 3.16376049e+08 0.5 m/s count
LHZ n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 3.16376049e+08 0.5 m/s count
BH1 n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 3.16376049e+08 1 m/s count
BH2 n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 3.16376049e+08 1 m/s count
HH1 n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 3.16376049e+08 1 m/s count
HH2 n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 3.16376049e+08 1 m/s count
LH1 n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 3.16376049e+08 0.5 m/s count
LH2 n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 3.16376049e+08 0.5 m/s count
HNE n/a TITAN n/a n/a n/a 855637.0 1.0 m/s**2 counts
HNN n/a TITAN n/a n/a n/a 855637.0 1.0 m/s**2 counts
HNZ n/a TITAN n/a n/a n/a 855637.0 1.0 m/s**2 counts
HNE n/a TITAN n/a n/a n/a 855637.0 1.0 m/s**2 counts
HNN n/a TITAN n/a n/a n/a 855637.0 1.0 m/s**2 counts
HNZ n/a TITAN n/a n/a n/a 855637.0 1.0 m/s**2 counts
BH1 n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 2.531008392e+09 1 m/s count
BH2 n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 2.531008392e+09 1 m/s count
BHZ n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 2.531008392e+09 1 m/s count
HH1 n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 2.531008392e+09 1 m/s count
HH2 n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 2.531008392e+09 1 m/s count
HHZ n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 2.531008392e+09 1 m/s count
LH1 n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 2.531008392e+09 0.5 m/s count
LH2 n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 2.531008392e+09 0.5 m/s count
LHZ n/a TRILLIUM-Compact broad band triaxial sensor by Nanometrics TRILLIUM-Compact n/a Q330SP data acquisition system by Kinemetrics 2.531008392e+09 0.5 m/s count

Basic Data:

Description
Start End Imported from FDSN Last FDSN sync
None None Nov. 20, 2019, 8:05 p.m. Nov. 20, 2019, 8:05 p.m.

Owner Data:

Firstname Lastname Department Agency City Street Country Phone Email
n/a n/a n/a n/a n/a n/a n/a n/a n/a

Morphology Data:

Description
Geological Unit Morphology Class Ground Type EC8 Groundwater Depth [m] Vs 30 [m/s] f0 [Hz] Amp(f0) Basin Flag Bedrock Depth [m]
0 0 0 0 False 0

Housing Data:

Description
Housing Class In Building? Number of storeys Distance to building
True 0 0

Borehole Data:

Depth [m]
0

Borehole Layers:

Description Top depth [m] Bottom depth [m]