Network | Code | Name | Latitude | Longitude | Elevation [m] | Status | Start | End | Created |
---|---|---|---|---|---|---|---|---|---|
Z3 | A338A | Semerovo, Nitriansky kraj, Slovakia | 48.015155 | 18.352506 | 154.00 | open | 2015/9/3 | 2022/12/31 | 2015/9/3 |
Channel | Sensor type | Sensor description | Sensor model | Sensor manufacturer | Datalogger | Sensitivity value | Sensitivity frequency | Input units name | Output units name |
---|---|---|---|---|---|---|---|---|---|
HH2 | n/a | RT151Bo, 60s, 2000 V/m/s, RT130S, Gain 1, 100 Hz | n/a | n/a | n/a | 724699000 | 0.05 | M/S | n/a |
HH3 | n/a | RT151Bo, 60s, 2000 V/m/s, RT130S, Gain 1, 100 Hz | n/a | n/a | n/a | 730516000 | 0.05 | M/S | n/a |
HHZ | n/a | RT151Bo, 60s, 2000 V/m/s, RT130S, Gain 1, 100 Hz | n/a | n/a | n/a | 726730000 | 0.05 | M/S | n/a |
LH2 | n/a | RT151Bo, 60s, 2000 V/m/s, RT130S, Gain 1, 1 Hz | n/a | n/a | n/a | 724699000 | 0.05 | M/S | n/a |
LH3 | n/a | RT151Bo, 60s, 2000 V/m/s, RT130S, Gain 1, 1 Hz | n/a | n/a | n/a | 730516000 | 0.05 | M/S | n/a |
LHZ | n/a | RT151Bo, 60s, 2000 V/m/s, RT130S, Gain 1, 1 Hz | n/a | n/a | n/a | 726730000 | 0.05 | M/S | n/a |
HH2 | n/a | RT151A, 60s, 2000 V/m/s, RT130S, Gain 1, 100 Hz | n/a | n/a | n/a | 726884000 | 0.05 | M/S | n/a |
HH3 | n/a | RT151A, 60s, 2000 V/m/s, RT130S, Gain 1, 100 Hz | n/a | n/a | n/a | 726884000 | 0.05 | M/S | n/a |
HHZ | n/a | RT151A, 60s, 2000 V/m/s, RT130S, Gain 1, 100 Hz | n/a | n/a | n/a | 726884000 | 0.05 | M/S | n/a |
LH2 | n/a | RT151A, 60s, 2000 V/m/s, RT130S, Gain 1, 1 Hz | n/a | n/a | n/a | 726884000 | 0.05 | M/S | n/a |
LH3 | n/a | RT151A, 60s, 2000 V/m/s, RT130S, Gain 1, 1 Hz | n/a | n/a | n/a | 726884000 | 0.05 | M/S | n/a |
LHZ | n/a | RT151A, 60s, 2000 V/m/s, RT130S, Gain 1, 1 Hz | n/a | n/a | n/a | 726884000 | 0.05 | M/S | n/a |
Description |
---|
Start | End | Imported from FDSN | Last FDSN sync |
---|---|---|---|
None | None | Nov. 20, 2019, 8:21 p.m. | Nov. 20, 2019, 8:21 p.m. |
Firstname | Lastname | Department | Agency | City | Street | Country | Phone | |
---|---|---|---|---|---|---|---|---|
n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
Description |
---|
Hillside |
Geological Unit | Morphology Class | Ground Type EC8 | Groundwater Depth [m] | Vs 30 [m/s] | f0 [Hz] | Amp(f0) | Basin Flag | Bedrock Depth [m] |
---|---|---|---|---|---|---|---|---|
Clay | Unknown | 0 | 0 | 0 | 0 | False | 0 |
Description |
---|
Sensor on ground floor of funeral house at cemetery, footprint: 15x15m. Building type: bricks. Building density: outside small village. Building usage: storage, occasionally funeral ceremonies. Sensor coupling: sensor placed on concrete floor. |
Housing Class | In Building? | Number of storeys | Distance to building |
---|---|---|---|
Building | True | 0 | 0 |
Depth [m] |
---|
0 |
Description | Top depth [m] | Bottom depth [m] |
---|