ORFEUS homepage
paginaheader  

 
paginaheader  
   
 

Changes in VEBSN dataless SEED at the ODC

Information on updates and known problems

NetworkStationProblem descriptionStatusDate of repairComments
BN EKB, WOL Stations are implemented in the VEBSN Dataless available 01/12/2004 -
CH BNALP, BOURR, FUORN, SENIN For all stations the normalization constant is not correct (set to 1). Repaired 14/01/2005 Detected by QCM
CH * Values for poles and zeros are not confirmed yet (different STS-2 generations). Detected - -
CZ DPC Sample rate at first decimation step is set to 0. This should be 2000. Detected - -
DK COP, MUD The normalization constant is not correct (set to 1) for the first stage. Detected - Detected by QCM
GB LRW Sensor and digitizer have been replaced since 2004/09/09. The 100s CMG-3T is replaced by a 120s CMG-3T, the Earthdata ED2400 digitizer is replaced by a Guralp DM24 digitizer. Detected - Lars Ottemuller (BGS)
 